Asepti RAPIDZYME PR

Multi-enzymatic medical instrument detergent class IIb enzymatic prion deactivator with biofilm remover

ARTG 156034

Asepti RAPIDZYME PR

Features

  • Asepti RAPIDZYME PR delivers validated efficacy for deactivation of human M1000* prions with the added benefit of universal material compatibility.
  • Asepti RAPIDZYME PR is a quadruple enzyme detergent with a near neutral pH concentration and is fully compatible with endoscopes, MIS and robotic instruments.
  • Asepti RAPIDZYME PR is ideal for reusable ultrasonic baths and will not promote bacterial growth for up to 24 hours and is suitable for all manual, soaking processes.
  • Asepti RAPIDZYME PR offers superior deactivation of human M1000* prions and can detach and remove biofilms (validated as per ISO 15883 – 5 Annex F).
  • Asepti RAPIDZYME PR complies with AS/NZS 5369:2023 and AS/NZS 4815:2014.

* Human M1000 Prion Strain – This prion strain has proven to be significantly more resistant to chemical and thermal deactivation than the scrapie-derived 263K prion strain used to validate World Health Organisation recommended prion deactivation cycles.

Alt Alt Alt Alt Alt Alt Alt Alt Alt Alt
Alt Alt Alt Alt Alt Alt Alt Alt Alt Alt
Product Code Product Description Pack Size Quote
5603301 Asepti RAPIDZYME PR Prior Deactivator, 5 L 2 Pk

Safety Information

Do not mix with any other products. For further information, safety instructions and health warnings, see product label and Safety Data Sheet.
ALWAYS READ THE LABEL. FOLLOW DIRECTIONS OF USE.

Directions For Use

  • Asepti RAPIDZYME PR standardises reprocessing by providing prion deactivation as an integrated component of all instrument cleaning, alleviating the inherent problems associated with risk classification of medical instrument loads.

For combined cleaning and human prion deactivation:

  • Remove gross contamination as per standard hospital instrument cleaning protocols.
  • Human prion deactivation cycle requires contact time of at least 30 minutes in Asepti RAPIDZYME PR diluted to 15-20 mL per litre of tap water and held at 50-65°C.
  • Rinse well, followed by autoclaving or chemical disinfection.
  • NB The World Health Organisation recommends the combination of at least two prion inactivating methods.

For routine instrument cleaning including endoscopes:

  • Remove gross contamination as per standard hospital instrument cleaning protocols.
  • Recommended contact time of at least 5 minutes in Asepti RAPIDZYME PR diluted to 5-15 mL per litre of tap water and held at 30-60°C.
  • Rinse well, followed by autoclaving or chemical disinfection.
  • Ensure that the cycle temperature does not exceed the limit recommended by the medical device manufacturer.
  • The majority of flexible endoscopes should not be exposed to temperatures above 60°C.
  • Also ensure that the cycle temperature does not exceed 70°C since the enzymes are deactivated above this temperature.
  • Asepti RAPIDZYME PR is supplied with two manual pumps.

Applications

  • Infection Control
  • Healthcare Facilities
  • Central Sterile Departments
  • Endoscopy

Relevant Product

Resources

  • safety data sheet (sds)
  • Video
  • Brochure

Downloads

To access a copy of the eBook or product brochure, please complete and submit a copy of the Downloads form below.